Heat generator control
With the Starter, you can manage when to turn on and off your heat generator (boiler or heat pump), to optimise its use, making it start up only when you really need it.
Download the Irsap Now App on for FREE and manage heating intelligently!
NO SUBSCRIPTION FEES!
Irsap Now is a free app with free updates
The IRSAP NOW Starter is the ideal solution, as it follows your lifestyle. It also helps you to save energy.
Starter is compatible with the majority of boilers and heat pumps on the market.
Control the Starter when and where you want with the IRSAP NOW app.
Schedule when to turn on your heat generator (boiler or heat pump).
Control your heat generator where and when from your smartphone via App and have it switch on automatically when you approach your home by activating geofencing.
With the Starter, you can manage when to turn on and off your heat generator (boiler or heat pump), to optimise its use, making it start up only when you really need it.
IRSAP Starter interfaces with modern heat generators (boilers or heat pumps) to optimise their functioning.
With the IRSAP NOW app, you can control your heat generator (boiler or heat pump) wherever and whenever you want. Thanks to wireless communication you can remotely manage when to turn on and off the heat generator (boiler or heat pump). Thanks to the wireless communication function, you can also manage the Smart Thermostat and Smart Valves installed on your radiators.
The IRSAP NOW System is compatible with all main voice assistants such as Google Home or Alexa. Find out how simple it is to change the setting of your system using your voice.
The Starter is compatible with most types of generator (boilers or heat pumps).
The Starter can be used with zone valves.
Replace your traditional thermostat with our Smart Thermostat with advanced functions for greater precision room temperature control, and air quality.
Control the temperature in every room without the need for any masonry or electrical work . Our Smart Valves are compatible with all types of radiators and products by major hydraulic valve manufacturers.
The Connection Unit is connected to the home router and is indispensable for controlling all the other devices in the system wherever and whenever you want directly from your smartphone via App.
Get the most out of your heating system with our modulating boiler and heat pump starter, which will allow you to optimise the use and activation of your boiler or any other heat generator.
Find out the solution
best suited to you
Frequent questions
The Starter is the element of the NOW System that allows you to manage the heat generator (boiler or heat pump). In addition, if your heat generator is ready for power modulation (you can check it on the boiler instruction booklet), IRSAP Starter can optimize its efficiency.
The Starter is powered by cable, by direct connection to the heat generator (boiler or heat pump) on which it is installed, or by connection to the electrical cables of the old thermostat, in case it is replaced.
The IRSAP NOW system optimizes the management of the heat generator (boiler or heat pump) to the maximum. This greatly reduces boiler ignitions, reducing consumption. According to studies conducted by the University of Bergamo on our first version of the NOW System, the reduction in energy consumption has reached 42%.
For this new version, studies are still ongoing: we will update this section as soon as the results are available.
If it is necessary to force the boiler or heat pump to turn on (e.g. for the annual control of the boiler), you will simply have to press the central button of the Starter: the boiler will turn on and the central button will flash red:
In general, the Starter is useful for all those who have an autonomous heating system, or in any case have the possibility to turn the boiler on/off. In addition, the Starter can replace a thermostat with remote control of the boiler.
IRSAP Starter is necessary if you already have a thermostat with remote control of the boiler or heat pump (e.g. radio frequency thermostat) or a boiler control module.
WARNING: If you have a boiler with a control unit and you want to replace the Starter, it is possible that by replacing the original module it is no longer possible to view all or some diagnostic data.
Contact your boiler technician for more information.
The Starter can be installed near the boiler or where there are direct connections with the heat generator (boiler or heat pump).
For information about installing and configuring the IRSAP NOW Starter Wizard, you can follow the following instructions or watch our Video Tutorial:
1. Remove the power supply to the boiler (recommended: remove the power supply from the whole house);
2. Check for lack of current (in case of lack of special instrumentation, detach the general generator);
3. Disassemble any previous control of the generator (thermostat or control unit);
4. Take a picture of the links present;
5. Mark the wires by inserting the stickers (present in the box) to distinguish them;
6. Disassemble any wall plate of the previous Starter;
7. Remove the back cover from our Starter module:
8. Attach the back cover to the wall:
9. Connect electrical wires based on the illustrations shown:
10. Apply the Starter to the back cover:
11. Restore power;
12. On the App, select "Menu --> Devices --> Add Device --> Starter";
13. Frame the QR Code or manually enter the code on the Starter, the app will automatically register the device by associating it with the system created;
14. If the QR code or numeric code is not readable, proceed to the emergency association: press the pairing button that you find on the front of the Connection Unit and then the pairing button on the front of the Starter.
The two devices will pair and you will receive a notification of association on the app: